Approx. Rs 20,000 / PieceGet Latest Price
Product BrochureProduct Details:Minimum Order Quantity | 1 Piece |
Voltage | 24 V |
Output Power | 960W |
Ripple Voltage | 24VDC |
Output Voltage | 24VDC |
Output Type | Single |
Number Of Channels | 1 |
Type | DIN-rail |
Mounting method | DIN rail |
Phase | Three |
Power output | 960 W |
Efficiency | 92 % |
Output voltage | 24 V |
Rated output current | 40 A |
Power boost ratio | 120 % |
Temperature range | -40-70 °C |
Features | Coated |
Terminal type | Screw |
Rated supply voltage at AC 50 Hz | 380-480 V |
Allowable supply voltage AC | 320-576 V |
Product Width (unpacked) | 135 mm |
Product Height (unpacked) | 125 mm |
Product Depth (unpacked) | 170 mm |
Approx. Rs 7,500 / PieceGet Latest Price
Product Details:Type | Analog |
Brand | OMRON |
Usage/Application | PANEL TIMER |
Rated Voltage | 24 to 48 VAC 50/60 Hz 24 to 48 VDC Ripple 20% max. |
Model Name/Number | OMRON TIMER H3DK-HBL |
Rated Current | 16A |
Mounting Type | Panel Mounting Timer |
Size | 22.5MM |
As of December 23, 2024
Rated power supply voltage | 24 to 48 VAC 50/60 Hz 24 to 48 VDC Ripple 20% max. |
---|---|
Allowable voltage variable range | 85 to 110% of the power supply voltage |
Power consumption | Approx. 1.2 VA (at 48 VAC) |
Number of time ranges | 2 |
Operation mode | Power OFF-delay |
Control output (Type) | Relay output (SPDT) |
Control output (Contact output) | Minimum applicable load: 100 mA at 5 VDC (failure level: P Reference value) |
Operating resetting | Instantaneous operation/Time-limit reset |
Ambient temperature range | Operating: -20 to 55 ℃ (with no icing) Storage: -40 to 70 ℃ (with no icing) |
Ambient humidity range | Operating: 25 to 85 % |
Accuracy of operating time | ±1% FS max. |
Setting error | ±10% FS ±0.05 s max. |
Influence of voltage | ±0.5% FS max. |
Influence of temperature | ±2% FS max. |
Insulation resistance | 100 MΩ min. (at 500 VDC) |
Dielectric strength | Between current carrying metal parts and non-current carrying metal parts: 2,000 VAC 50/60 Hz 1 min Between control output terminals and operating circuit: 2,000 VAC 50/60 Hz 1 min Between non-continuous contacts: 1,000 VAC 50/60 Hz 1 min |
Impulse withstand voltage | Between power terminals: 1 kV Between current carrying terminals and exposed non-current carrying metal parts: 1.5 kV |
Noise immunity | ±1.5 kV (between power terminals), square-wave noise by noise simulator (pulse width: 100 ns/1 µs, 1-ns rise) |
Static immunity | Mulfunction: 4 kV, Destruction: 8 kV |
Vibration resistance | Destruction: 10 to 55 Hz, 0.75 mm single amplitude each in 3 directions for 2 h Malfunction: 10 to 55 Hz, 0.5 mm single amplitude each in 3 directions for 10 min |
Shock resistance | Destruction: 1,000 m/s2, 3 times each in 6 directions Malfunction: 100 m/s2, 3 times each in 6 directions |
Life expectancy (relay output) | Electrical: 100,000 operations min. (5 A at 250 VAC, resistive load at 1200 operations/h) Mechanical: 10 million operations min. (under no load at 1,200 operations/h) |
Degree of protection | IP30 (Terminal Block: IP20) |
Connecting method | Terminal blocks |
Weight | Approx. 120 g |
Accessories | User label |